New Gold, Isolation & Ultra Transformer, Control Transformer, Auto Transformer (Single Phase, Two Phase & Three Phases). This Transformer can also be developed into step up & step down. The voltage range is 10 V to 5000 volt, & frequency 25 Hz to 500 Hz (General use 50 Hz & 60 Hz). These Isolation Transformers reduce the effects of power line problems like Noise, Spikes, Surges Transients and neutral to a minimum.
CARE DISCRIPTION OF MACHINE & INSTRUMENT: - Switching of electrical utilities in industrial & commercial environment generates spikes up to 6000 Volt & high frequency power line noises.
The spikes can cause the failure of thrusters, micro-processors, or other active electronic device.
The high frequency noises can interfere with Digital-Electronic equipment causing data corruption, erratic behavior, loss of memory etc.
The noise cut-off transformer eliminates such noises & attenuates the spikes to negligible values, providing complete protection against such electrical disturbances. APPLICATION:-
• Protect the CNC Machines, computer and Telecommunications equipment from damage due to electrical noise, spikes etc. • Where ground potential of system units are different from each other and are exposed to the effects of instability at high frequencies. • Where ground of the equipment cannot be earthed. • When no slightest current leakage is permitted in the equipment. Especially for computers and CNC controls less then 100 micro Amps is only permitted. • To protect against strong lighting, impulse noise, bus short- circuit, accidental discharge of capacitors etc. When no slightest current leakage is permitted in the equipment. • To shield large number of electronic equipment which individually also are producing different type of electrical noise at a common busbar typically CNC machines, Drives, hardening equipment etc.
TECHNICAL SPECIFICATION: -
• System Connections
Voltage design as per customer require voltage 10 volt to 5000 volt in single phase & three phase Design for frequency 25 Hz to 500Hz (General use 47 Hz to 60 Hz)
• Ratios
• Regulation
• Di-electric strength • Insulation Resistance • Coupling Capacitance • Leakage Current
• Common Model attenuation
• Construction Standards
|
Delta/ Star, Star/Delta , Star/Star (and in Single
phase Series & panel connection)
1:1 and 2:1(or as per customer requirement) Better than 3.5 % 2500 V AC for 120 Sec More than 1000 Mega Ohms. 0.1 PF for 100 db Less than 20 mocro Amps. 100db As per is 2026 part 1 &11 |
 |
 |
 |
| (01)2 KVA 3 PHASE ISOLATION TRANSFORMER |
(02)7.5 KVA 3 PHASE ISOLATION TRANSFORMER |
(03)10 KVA 3 PHASE ISOLATION TRANSFORMER |
 |
 |
 |
| (04)1 KVA 3 PHASE ISOLATION TRANSFORMER |
(05) ULTRA ISOLATION TRANSFORMER |
(06) HT TRANSFORMER UIT TYPE |
 |
|
|
| (07)50 KVA 3 PHASE ISOLATION TRANSFORMER |
(08) SIDE VIEW OF TRANSFORMER |
|
Related Posts
|
NEWGOLD High Frequency motorized spindles and motors have been servicing and rewinding last 25 years, in world label reputed companies just as GMN, GAMFIOR, IBAG, VOUMARD etc. Completely service rewinding ball bearing fitting and vibration balancing ...
|
|
|
NEWGOLD High Frequency motorized spindles and motors have been servicing and rewinding last 25 years, in world label reputed companies just as GMN, GAMFIOR, IBAG, VOUMARD etc. Completely service rewinding ball bearing fitting and vibration balancing ...
|
|
|
NEWGOLD High Frequency motorized spindles and motors have been servicing and rewinding last 25 years, in world label reputed companies just as GMN, GAMFIOR, IBAG, VOUMARD etc. Completely service rewinding ball bearing fitting and vibration balancing ...
|
|
|