New Gold, Isolation & Ultra Transformer, Control Transformer, Auto Transformer (Single Phase, Two Phase & Three Phases). This Transformer can also be developed into step up & step down. The voltage range is 10 V to 5000 volt, & frequency 25 Hz to 500 Hz     (General use 50 Hz & 60 Hz).
These Isolation Transformers reduce the effects of power line problems like Noise, Spikes, Surges Transients and neutral to a minimum.

CARE DISCRIPTION OF MACHINE & INSTRUMENT: -
Switching of electrical utilities in industrial & commercial environment generates spikes up to 6000 Volt & high frequency power line noises.

The spikes can cause the failure of thrusters, micro-processors, or other active electronic device.

The high frequency noises can interfere with Digital-Electronic equipment causing data corruption, erratic behavior, loss of memory etc.

The noise cut-off transformer eliminates such noises & attenuates the spikes to negligible values, providing complete protection against such electrical disturbances.
 
APPLICATION:-


•    Protect the CNC Machines, computer and Telecommunications equipment from damage due to electrical noise, spikes etc.
•    Where ground potential of system units are different from each other and are exposed to the effects of instability at high frequencies.
•    Where ground of the equipment cannot be earthed.
•   When no slightest current leakage is permitted in the equipment. Especially for computers and CNC controls less then 100 micro Amps is only permitted.
•    To protect against strong lighting, impulse noise, bus short- circuit, accidental discharge of capacitors etc. When no slightest current leakage is permitted in the equipment.
•    To shield large number of electronic equipment which individually also are producing different type of electrical noise at a common busbar typically CNC machines, Drives, hardening equipment etc.

TECHNICAL SPECIFICATION: -


 •    System Connections
Voltage design as per customer require voltage 10 volt to 5000 volt in single phase & three phase Design for frequency 25 Hz to 500Hz (General use 47 Hz to 60 Hz)
•    Ratios
•    Regulation
•    Di-electric strength
•    Insulation Resistance
•    Coupling Capacitance
•    Leakage Current
•    Common Model attenuation
•    Construction Standards
Delta/ Star, Star/Delta , Star/Star (and in Single
phase Series & panel connection)



1:1 and 2:1(or as per customer requirement)
Better than 3.5 %
2500 V AC for 120 Sec
More than 1000 Mega Ohms.
0.1 PF for 100 db
Less than 20 mocro Amps.
100db
As per is 2026 part 1 &11


image image image
(01)2 KVA 3 PHASE ISOLATION TRANSFORMER (02)7.5 KVA 3 PHASE ISOLATION TRANSFORMER (03)10 KVA 3 PHASE ISOLATION TRANSFORMER
image image image
(04)1 KVA 3 PHASE ISOLATION TRANSFORMER (05) ULTRA ISOLATION TRANSFORMER (06) HT  TRANSFORMER UIT TYPE
image image  
(07)50 KVA 3 PHASE ISOLATION TRANSFORMER (08) SIDE VIEW OF TRANSFORMER  

   