New Gold, Isolation & Ultra Transformer, Control Transformer, Auto Transformer (Single Phase, Two Phase & Three Phases). This Transformer can also be developed into step up & step down. The voltage range is 10 V to 5000 volt, & frequency 25 Hz to 500 Hz (General use 50 Hz & 60 Hz).
These Isolation Transformers reduce the effects of power line problems like Noise, Spikes, Surges Transients and neutral to a minimum.
CARE DISCRIPTION OF MACHINE & INSTRUMENT: -
Switching of electrical utilities in industrial & commercial environment generates spikes up to 6000 Volt & high frequency power line noises.
The spikes can cause the failure of thrusters, micro-processors, or other active electronic device.
The high frequency noises can interfere with Digital-Electronic equipment causing data corruption, erratic behavior, loss of memory etc.
The noise cut-off transformer eliminates such noises & attenuates the spikes to negligible values, providing complete protection against such electrical disturbances.
APPLICATION:-
• Protect the CNC Machines, computer and Telecommunications equipment from damage due to electrical noise, spikes etc.
• Where ground potential of system units are different from each other and are exposed to the effects of instability at high frequencies.
• Where ground of the equipment cannot be earthed.
• When no slightest current leakage is permitted in the equipment. Especially for computers and CNC controls less then 100 micro Amps is only permitted.
• To protect against strong lighting, impulse noise, bus short- circuit, accidental discharge of capacitors etc. When no slightest current leakage is permitted in the equipment.
• To shield large number of electronic equipment which individually also are producing different type of electrical noise at a common busbar typically CNC machines, Drives, hardening equipment etc.
TECHNICAL SPECIFICATION: -
• System Connections
Voltage design as per customer require voltage 10 volt to 5000 volt in single phase & three phase Design for frequency 25 Hz to 500Hz (General use 47 Hz to 60 Hz)
• Ratios
• Regulation
• Di-electric strength • Insulation Resistance • Coupling Capacitance • Leakage Current
• Common Model attenuation
• Construction Standards
|
Delta/ Star, Star/Delta , Star/Star (and in Single
phase Series & panel connection)
1:1 and 2:1(or as per customer requirement) Better than 3.5 % 2500 V AC for 120 Sec More than 1000 Mega Ohms. 0.1 PF for 100 db Less than 20 mocro Amps. 100db As per is 2026 part 1 &11 |
 |
 |
 |
| (01)2 KVA 3 PHASE ISOLATION TRANSFORMER |
(02)7.5 KVA 3 PHASE ISOLATION TRANSFORMER |
(03)10 KVA 3 PHASE ISOLATION TRANSFORMER |
 |
 |
 |
| (04)1 KVA 3 PHASE ISOLATION TRANSFORMER |
(05) ULTRA ISOLATION TRANSFORMER |
(06) HT TRANSFORMER UIT TYPE |
 |
|
|
| (07)50 KVA 3 PHASE ISOLATION TRANSFORMER |
(08) SIDE VIEW OF TRANSFORMER |
|